Open Tem Cells for EMC Pre-Compliance Testing

Septum Height:

A TEM cell is a stripline device for radiated emissions and immunity testing of electronic devices. It is not a replacement, but due to its size and cost it is a convenient alternative to measurements in an anechoic chamber.

A TEM cell consists of a septum, the conductive strip in the centre section and walls which are connected to ground. The geometry is designed to present a 50Ω stripline. The device under test (DUT) is placed in between the bottom wall and the septum.

Model: -. Category: . Tags: .
Share:

Specifications

  • TBTC0 TEM cell
    • Dimensions
      • Length: 390 mm
      • Width: 100 mm
      • Height: 62 mm
      • Septum height: 28 mm
      • Rectangular area under the septum: 19 cm x 7 cm x 2,8 cm
    • TEM cell connectors: N-female
    • Nominal cell impedance: 50 Ohm
    • Wave impedance: 377 Ohm
    • Maximum RF input power: 10W (limited by supplied 50 Ohm Termination)
    • Input return loss: S11 up to 3.15 GHz < -15dB
    • Transmission loss: up to 3 GHz < 3dB, up to 6 GHz < 4dB

  • TBTC1 TEM cell
    • Dimensions
      • Length: 390 mm
      • Width: 200 mm
      • Height: 108 mm
      • Septum height: 50 mm
      • Rectangular area under the septum: 19 cm x 13 cm x 5 cm
    • TEM cell connectors: N-female
    • Nominal cell impedance: 50 Ohm
    • Wave impedance: 377 Ohm
    • Maximum RF input power: 25W (limited by supplied 50 Ohm Termination)
    • Input return loss: S11 up to 1.2 GHz < -20dB, up to 2.1 GHz < -17dB, up to 3GHz < -14dB
    • Transmission loss: up to 1.4 GHz < 1 dB, up to 2.1 GHz < 3dB, up to 3 GHz < 6dB

  • TBTC2 TEM cell
    • Dimensions
      • Length: 636 mm
      • Width: 300 mm
      • Height: 205 mm
      • Septum height: 100 mm
      • Rectangular area under the septum: 23 cm x 28 cm x 10 cm
    • TEM cell connectors: N-female
    • Nominal cell impedance: 50 Ohm
    • Wave impedance: 377 Ohm
    • Maximum RF input power: 25W (limited by supplied 50 Ohm Termination)
    • Input return loss: S11 up to 800 MHz < -15dB, up to 1.5 GHz < -10dB, up to 3GHz < -8dB
    • Transmission loss: up to 800 MHz < 1 dB, up to 1.15 GHz < 3dB

  • TBTC3 TEM cell
    • Dimensions
      • Length: 1038 mm
      • Width: 501 mm
      • Height: 305 mm
      • Septum height: 150 mm
      • Rectangular area under the septum: 36 cm x 48 cm x 15 cm
    • TEM cell connectors: N-female
    • Nominal cell impedance: 50 Ohm
    • Wave impedance: 377 Ohm
    • Maximum RF input power: 25W (limited by supplied 50 Ohm Termination)
    • Input return loss: S11 up to 700 MHz < -16dB
    • Transmission loss: up to 730 MHz < 3 dB

  • DC-Block 50V-6GHz-N
    • Connectors: N-Male/Female
    • Nominal impedance: 50 Ohm
    • Max. continuous RF power: 2W
    • Max. continuous RF voltage: 50V RMS
    • Frequency: 500kHz to 6 GHz
    • VSWR: ≤ 1.2

  • RF-Termination 50Ω-3GHz-25W-N
    • Connector: N-Male
    • Nominal impedance: 50 Ohm
    • Max. continuous RF power: 25W
    • Frequency: DC to 3 GHz
    • VSWR: ≤ 1.2
    • Third order intermodulation: ≤ 120 dBc

100% Original Brands

We guarantee you the sale of Original Brands with warranties.