Open Tem Cells for EMC Pre-Compliance Testing
Septum Height:
A TEM cell is a stripline device for radiated emissions and immunity testing of electronic devices. It is not a replacement, but due to its size and cost it is a convenient alternative to measurements in an anechoic chamber.
A TEM cell consists of a septum, the conductive strip in the centre section and walls which are connected to ground. The geometry is designed to present a 50Ω stripline. The device under test (DUT) is placed in between the bottom wall and the septum.
Specifications
- TBTC0 TEM cell
- Dimensions
- Length: 390 mm
- Width: 100 mm
- Height: 62 mm
- Septum height: 28 mm
- Rectangular area under the septum: 19 cm x 7 cm x 2,8 cm
- TEM cell connectors: N-female
- Nominal cell impedance: 50 Ohm
- Wave impedance: 377 Ohm
- Maximum RF input power: 10W (limited by supplied 50 Ohm Termination)
- Input return loss: S11 up to 3.15 GHz < -15dB
- Transmission loss: up to 3 GHz < 3dB, up to 6 GHz < 4dB
- Dimensions
- TBTC1 TEM cell
- Dimensions
- Length: 390 mm
- Width: 200 mm
- Height: 108 mm
- Septum height: 50 mm
- Rectangular area under the septum: 19 cm x 13 cm x 5 cm
- TEM cell connectors: N-female
- Nominal cell impedance: 50 Ohm
- Wave impedance: 377 Ohm
- Maximum RF input power: 25W (limited by supplied 50 Ohm Termination)
- Input return loss: S11 up to 1.2 GHz < -20dB, up to 2.1 GHz < -17dB, up to 3GHz < -14dB
- Transmission loss: up to 1.4 GHz < 1 dB, up to 2.1 GHz < 3dB, up to 3 GHz < 6dB
- Dimensions
- TBTC2 TEM cell
- Dimensions
- Length: 636 mm
- Width: 300 mm
- Height: 205 mm
- Septum height: 100 mm
- Rectangular area under the septum: 23 cm x 28 cm x 10 cm
- TEM cell connectors: N-female
- Nominal cell impedance: 50 Ohm
- Wave impedance: 377 Ohm
- Maximum RF input power: 25W (limited by supplied 50 Ohm Termination)
- Input return loss: S11 up to 800 MHz < -15dB, up to 1.5 GHz < -10dB, up to 3GHz < -8dB
- Transmission loss: up to 800 MHz < 1 dB, up to 1.15 GHz < 3dB
- Dimensions
- TBTC3 TEM cell
- Dimensions
- Length: 1038 mm
- Width: 501 mm
- Height: 305 mm
- Septum height: 150 mm
- Rectangular area under the septum: 36 cm x 48 cm x 15 cm
- TEM cell connectors: N-female
- Nominal cell impedance: 50 Ohm
- Wave impedance: 377 Ohm
- Maximum RF input power: 25W (limited by supplied 50 Ohm Termination)
- Input return loss: S11 up to 700 MHz < -16dB
- Transmission loss: up to 730 MHz < 3 dB
- Dimensions
- DC-Block 50V-6GHz-N
- Connectors: N-Male/Female
- Nominal impedance: 50 Ohm
- Max. continuous RF power: 2W
- Max. continuous RF voltage: 50V RMS
- Frequency: 500kHz to 6 GHz
- VSWR: ≤ 1.2
- RF-Termination 50Ω-3GHz-25W-N
- Connector: N-Male
- Nominal impedance: 50 Ohm
- Max. continuous RF power: 25W
- Frequency: DC to 3 GHz
- VSWR: ≤ 1.2
- Third order intermodulation: ≤ 120 dBc
TBTC Manual
Q&A Open TEM Cells
EMC pre compliance testing guide
Application Note: Radiated Noise Measurement example using Tekbox TEM Cells
Application Note: Immunity testing example using Tekbox TEM Cells
TBTC 1 insertion loss (S21)
TBTC 2 insertion loss (S21)
TBTC 3 insertion loss (S21)
EMCview PC software for EMC pre-compliance testing
100% Original Brands
We guarantee you the sale of Original Brands with warranties.